Loading...
F 4.1 4
F_4.1_01_GB.fm 4-8
For filling in the oil:
- Unscrew inspection plug (A) and the
filling plug (B).
- Fill oil of the correct specification
through the filling hole (B) until the oil
level reaches the lower edge of the in-
spection hole (A).
- Replace the filling in plug (B) and the
inspection plug (A).
For changing the oil:
A
Change the oil when the engine is at op-
erating temperature.
- Unscrew filling plug (B) and the drain
plug (C).
- Drain the oil
- Drive in the oil drain plug (C) again.
- Remove the inspection plug (A).
- Fill oil of the correct specification
through the filling hole (B) until the oil
level reaches the lower edge of the in-
spection hole (A).
- Replace the filling in plug (B) and the inspection plug (A).
Drive chain (3) of the transport augers
Checking of chain tightness:
- Turn the auger by hand to the right
and to the left. The free play (C) shall
be now 13 to 15 mm measured on the external perimeter of the auger segments.