Start-up
Step Action
1 Switch on the voltage. Press the start button for at least 3 seconds.
If the motor rotation direction is correct, the compressor starts.
If the rotation direction of the motor is incorrect, the compressor doesn’t start and the
controller display will show an alarm. Switch off the voltage, open the isolating
(disconnecter) switch (IG) and reverse two phases of the supply cable. Switch on the
voltage and restart the compressor. The shutdown message will disappear automatically
when the shutdown condition has disappeared
2 Start and run the compressor for a few minutes. Check that the compressor is operating
normally.
5.2 Starting
Air outlet valve on air receiver
Condensate drain valve on air receiver
Dew point temperature gauge
Instruction book
2920 7119 21 53