CSA/UL versions
For UL designed machines, calculations of cable sections are done according to UL508A
(Industrial control panels).
For CSA, calculations of cable sections are done according to CSA 22.2 (Canadian electrical
code).
Standard conditions refer to:
Maximum 3 copper conductors in raceway or cable with 85-90˚C (185-194 ˚F) insulation at
ambient temperature 30 ˚C (86 ˚F), operating at nominal voltage; cables not grouped with other
cables.
Worst case conditions refer to:
Ambient temperature > 30 °C (86 °F).
Maximum 3 copper conductors in raceway or cable with 85-90 ˚C (185-194 ˚F) insulation at
46 ˚C (115 ˚F) ambient temperature and operating at nominal voltage.
Cables not grouped with other cables.
If the local conditions are more severe then the described standard conditions, the cables for
worst case conditions should be used.
Recommended cable size
Pack version – PVC 70 °C / XLPE-EPR 90 °C
G 15L G 18 G 22
Frequency
(Hz)
Voltage
(V)
Cable size Cable size Cable size
IEC
50 230
25 mm
2
/ 16 mm
2
50 mm
2
/ 25 mm
2
70 mm
2
/ 35 mm
2
50 400
10 mm
2
/ 10 mm
2
16 mm
2
/ 10 mm
2
25 mm
2
/ 16 mm
2
60 230
25 mm
2
/ 16 mm
2
50 mm
2
/ 25 mm
2
70 mm
2
/ 35 mm
2
60 380
16 mm
2
/ 10 mm
2
25 mm
2
/ 10 mm
2
25 mm
2
/ 16 mm
2
60 460
16 mm
2
/ 6 mm
2
16 mm
2
/ 10 mm
2
25 mm
2
/ 10 mm
2
CSA/UL
60 200 AWG4 AWG3 AWG1
60 230 AWG4 AWG3 AWG1
60 460 AWG8 AWG8 AWG8
60 575 AWG8 AWG8 AWG6
Full-Feature version – PVC 70 °C / XLPE-EPR 90 °C
G 15L G 18 G 22
Frequency
(Hz)
Voltage
(V)
Cable size Cable size Cable size
IEC
50 230
50 mm
2
/ 25 mm
2
50 mm
2
/ 35 mm
2
70 mm
2
/ 35 mm
2
50 400
400+N
16 mm
2
/ 10 mm
2
16 mm
2
/ 10 mm
2
25 mm
2
/ 16 mm
2
Instruction book
2920 7119 21 77