139
Instruction book
9096 3321 00
Units
7.5 bar 8 bar 10 bar 13 bar
l/min
70 70 70 70
Oil capacity, air-cooled units
l
23 23 23 23
Oil capacity, water-cooled
units
l
22 22 22 22
Sound pressure level,
Workplace and workplace
Full-Feature (according to
ISO 2151 (2004))
dB(A)
67 67 67 66
Cooling water consumpation
( at water inlet temperature
between 35 and 40
0
C
temperature rise of 10
0
C ),
water cooled units
Units
7.5 bar 8 bar 10 bar 13 bar
Frequency
Hz
50 50 50 50
Maximum
(unloading)
pressure, units
without dryer
bar(e)
7.5 8 10 13
Maximum
(unloading)
pressure, Full-
Feature units
bar(e)
7.25 7.75 9.75 12.75
Reference working
pressure, units
without dryer
bar(e) 7 7 9.5 12.5
Reference working
pressure,
Workplace Full-
Feature units
bar(e) 7 8 9.5 12.5
Pressure drop over
dryer, Full-Feature
units
bar(e) 0.23 0.12 0.14 0.08
GA 55