140
Instruction book
9096 3321 00
Units
7.5 bar 8 bar 10 bar 13 bar
Set point,thermostatic
valve
40 40 40 65
Temperature of air leaving
outlet valve (approx),air-
cooled units without dryer
30 30 30 30
Temperature of air leaving
outlet valve (approx),water-
cooled units without dryer
32 32 32 32
Temperature of air leaving
outlet valve (approx.),Full-
Feature units
25 25 25 25
Pressure dewpoint,Full-
Feature units
4 4 4 4
Drive motor,
SIEMENS
1LG9
228-2
1LG9
228-2
1LG9
228-2
1LG9
228-2
Motor shaft speed
r/min 2965 2965 2965 2965
Nominal motor
rating
kW 55 55 55 55
Power consumpation
Dryer at full load,
Full-Feature units
kW 2.7 2.7 2.7 2.7
Power consumption dryer at
full load,Full-Feature units
(1)
kW 1.6 1.6 1.2 1.4
Power consumpation
Dryer at no load, Full-
Feature units
kW 2.4 2.4 2.4 2.4
Power consumpation
Dryer at no load, Full-
Feature units (1)
kW 1.4 1.4 1.1 1.3
0
C
0
C
0
C
0
C
0
C