143
Instruction book
9096 3321 00
Units
7.5 bar 8 bar 10 bar 13 bar
Power consumption dryer at
full load,Full-Feature units
(1)
kW 1.6 1.6 1.6 1.2
Power consumpation
Dryer at no load, Full-
Feature units
kW 2.4 2.4 2.4 2.4
Power consumpation
Dryer at no load, Full-
Feature units (1)
kW 1.4 1.4 1.4 1.1
Refrigerant type,Full-Feature
units
R404a R404a R404a R404a
Refrigerant type,Full-Feature
units (1)
R410A R410A R410A R410A
Refrigerant quantity, Full-
Feature units
kg 1.4 1.4 1.4 1.4
Refrigerant quantity, Full-
Feature units (1)
kg 0.97 0.97 0.97 1.00
Oil capacity, air-cooled units
l
25 25 25 25
Oil capacity, water-cooled
units
l
22 22 22 22
Sound pressure level,
Workplace and workplace
Full-Feature (according to
ISO 2151 (2004))
dB(A)
70 70 70 70