2920 1251 02
38
Instruction book
7.5.6 Specific data of GA/GA W 90 up to -160 100 psi - 60 Hz 1)
Compressor type 90 110 160 90 W 110 W 160 W
Maximum working pressure . . . . . . . . . . bar(e) 7.4 7.4 7.4 7.4 7.4 7.4
Nominal working pressure . . . . . . . . . . . bar(e) 6.9 6.9 6.9 6.9 6.9 6.9
Air temperature at outlet valve, approx. °C27 2830282830
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1785 1790 1790 1785 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . . kW 108 129 176 104 125 169
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 75 75 80 75 80 80
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 76 77 78 74 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 2.0 2.4 3.4
7.5.7 Specific data of GA/GA W 90 up to -160 125 psi - 60 Hz 1)
Compressor type 90 110 160 90 W 110 W 160 W
Maximum working pressure . . . . . . . . . . bar(e) 9.1 9.1 9.1 9.1 9.1 9.1
Nominal working pressure . . . . . . . . . . . bar(e) 8.6 8.6 8.6 8.6 8.6 8.6
Air temperature at outlet valve, approx. °C27 2830282830
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1785 1790 1790 1785 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . . kW 108 129 174 104 125 166
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 75 75 80 75 80 80
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 76 77 78 74 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 2.0 2.4 3.4
7.5.8 Specific data of GA/GA W 90 up to -160 150 psi - 60 Hz 1)
Compressor type 90 110 160 90 W 110 W 160 W
Maximum working pressure . . . . . . . . . . bar(e) 10.8 10.8 10.8 10.8 10.8 10.8
Nominal working pressure . . . . . . . . . . . bar(e) 10.3 10.3 10.3 10.3 10.3 10.3
Air temperature at outlet valve, approx. °C27 2830282830
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1785 1790 1790 1785 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . . kW 109 128 173 105 124 165
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 75 75 80 75 75 80
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 76 77 78 74 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 2.0 2.4 3.4
1) At reference conditions (see section 7.5.1)
2) According to PNEUROP/CAGI at 1 m distance under free field conditions with a tolerance of 3 dB
3) For GA including cooling fans. Values may differ up to 0.5% depending on the supply voltage