2920 1251 02
39
Instruction book
7.5.9 Specific data of GA/GA W 90 up to -160 200 psi - 60 Hz 1)
Compressor type 90 110 160 90 W 110 W 160 W
Maximum working pressure . . . . . . . . . . bar(e) 13.8 13.8 13.8 13.8 13.8 13.8
Nominal working pressure . . . . . . . . . . . bar(e) 13.3 13.3 13.3 13.3 13.3 13.3
Air temperature at outlet valve, approx. °C27 2830282830
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1785 1790 1790 1785 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . . kW 108 128 178 104 125 171
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 75 75 80 75 75 80
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 76 77 78 74 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 2.0 2.4 3.4
7.5.10 Specific data of GA/GA W 200 and -250 7.5 bar - 50 Hz 1)
Compressor type 200 250 200 W 250 W
Maximum working pressure . . . . . . . . . . . . . . . . . . . . . . bar(e) 7.5 7.5 7.5 7.5
Nominal working pressure . . . . . . . . . . . . . . . . . . . . . . . bar(e) 7 7 7 7
Air temperature at outlet valve, approx. . . . . . . . . . . . . °C30303030
Motor shaft speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . r/min 1490 1490 1490 1490
Power input 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kW 215 267 207 260
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l 125 125 125 125
Sound pressure level 2) . . . . . . . . . . . . . . . . . . . . . . . . . dB(A) 75 75 75 75
Cooling water flow at temperature rise of 10°C . . . . . . l/s -- -- 3.9 4.9
7.5.11 Specific data of GA/GA W 200 and -250 10/13 bar - 50 Hz 1)
Compressor type 200 250 200 W 250 W 250 250 W
Maximum working pressure . . . . . . . . . . bar(e) 10 10 10 10 13 13
Nominal working pressure . . . . . . . . . . . bar(e) 9.5 9.5 9.5 9.5 12.5 12.5
Air temperature at outlet valve, approx. °C30 3030303030
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1480 1485 1490 1490 1490 1490
Power input 3) . . . . . . . . . . . . . . . . . . . . kW 211 266 203 259 273 265
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 125 125 125 125 125 125
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 75 75 75 75 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- 3.9 4.9 -- 4.9
1) At reference conditions (see section 7.5.1)
2) According to PNEUROP/CAGI at 1 m distance under free field conditions with a tolerance of 3 dB
3) For GA including cooling fans. Values may differ up to 0.5% depending on the supply voltage