2920 1251 02
40
Instruction book
7.5.12 Specific data of GA/GA W 200 up to -315 100 psi - 60 Hz 1)
Compressor type 200 250 315 200 W 250 W 315 W
Maximum working pressure . . . . . . . . . . bar(e) 7.4 7.4 7.4 7.4 7.4 7.4
Nominal working pressure . . . . . . . . . . . bar(e) 6.9 6.9 6.9 6.9 6.9 6.9
Air temperature at outlet valve, approx. °C30 3030303030
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1790 1790 1790 1790 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . . kW 223 267 292 210 254 279
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 125 125 125 125 125 125
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 78 78 78 75 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 3.9 4.8 5.3
7.5.13 Specific data of GA/GA W 200 up to -315 125 psi - 60 Hz 1)
Compressor type 200 250 315 200 W 250 W 315 W
Maximum working pressure . . . . . . . . . . bar(e) 9.1 9.1 9.1 9.1 9.1 9.1
Nominal working pressure . . . . . . . . . . . bar(e) 8.6 8.6 8.6 8.6 8.6 8.6
Air temperature at outlet valve, approx. °C30 3030303030
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1790 1790 1790 1790 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . kW 222 265 296 209 252 283
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 125 125 125 125 125 125
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 78 78 78 75 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 3.9 4.8 5.3
7.5.14 Specific data of GA/GA W 200 up to -315 150 psi - 60 Hz 1)
Compressor type 200 250 315 200 W 250 W 315 W
Maximum working pressure . . . . . . . . . . bar(e) 10.8 10.8 10.8 10.8 10.8 10.8
Nominal working pressure . . . . . . . . . . . bar(e) 10.3 10.3 10.3 10.3 10.3 10.3
Air temperature at outlet valve, approx. °C30 3030303030
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min 1790 1790 1790 1790 1790 1790
Power input 3) . . . . . . . . . . . . . . . . . . . kW 226 263 295 213 250 282
Oil capacity. . . . . . . . . . . . . . . . . . . . . . . l 125 125 125 125 125 125
Sound pressure level 2) . . . . . . . . . . . . . dB(A) 78 78 78 75 75 75
Cooling water flow at temperature
rise of 10°C. . . . . . . . . . . . . . . . . . . . . . . l/s -- -- -- 3.9 4.8 5.3
1) At reference conditions (see section 7.5.1)
2) According to PNEUROP/CAGI at 1 m distance under free field conditions with a tolerance of 3 dB
3) For GA including cooling fans. Values may differ up to 0.5% depending on the supply voltage