         Control panel Elektronikon Graphic
Step Action 
-  Switch on the voltage. Check that voltage on LED (6) lights up. 
-  Open the air outlet valve. 
-  Press start button (1) on the control panel. The compressor starts running and the 
automatic operation LED (8) lights up. Ten seconds after starting, the drive motor 
switches over from star to delta and the compressor starts running loaded. 
-  On water-cooled compressors, regulate the cooling water flow during  loaded running 
to obtain the most suitable temperature at the outlet of the compressor element, i.e. 
between 2
o
C and 7
o
C above the relevant temperature in the figure below. For 
optimum operation, the cooling water outlet temperature must never exceed the valve 
specified in section Compressor data. Consult Atlas Copco if condensate should form 
during frequent unloading periods.