140
Instruction book
9096 3313 00
(1): from approx. April 30, 2009 onwards
GA 90
  Units  7.5 bar  8 bar  10 bar  13 bar 
Frequency  Hz  50  50  50  50 
Maximum 
(unloading) 
pressure, units 
without dryer 
bar(e)  7.5  8  10  13 
Maximum 
(unloading) 
pressure, Full-
Feature units 
bar(e)  7.25  7.75  9.75  12.75 
Reference working 
pressure, units without 
dryer 
bar(e)  7  8  9.5  12.5 
Reference working 
pressure, Full-Feature 
units 
bar(e)  7  7.75  9.5  12.5 
Pressure drop 
over dryer, Full-
Feature units 
bar(e)  0.2  0.2  0.2  0.2 
Set point, thermostatic 
valve 
°C  40  40  40  60 
Temperature of air 
leaving outlet valve 
(approx.), units without 
dryer 
°C  30  30  30  30 
Temperature of air 
leaving outlet valve 
(approx.), Full-
Feature units 
°C  25  25  25  25 
Pressure dew-point, 
Full-Feature units 
°C  3  3  3  3 
Drive motor, SIEMENS 
  1LG6 259-
2 
1LG6 259-2  1LG6 259-2  1LG6 259-2 
Motor shaft speed  r/min  2978 2978  2978  2978 
Nominal motor rating  kW  90  90  90  90 
Power 
consumption dryer 
at full load, Full-
Feature units 
kW  4.7  4.2  4.2  3.2 
Power 
consumption dryer 
at full load, Full-
Feature units (1) 
kW  2.5  2.0  2.0  1.6 
Power consumption 
dryer at no load, 
Full-Feature units 
kW  3.9  3.4  3.4  2.4 
Power consumption 
dryer at no load, 
Full-Feature units 
(1) 
kW  2.3  1.5  1.5  1.4