The engine oil should be replaced after the first
8 hours of operation and thereafter in
accordance with the maintenance schedule in
the engine manufacturer's operating and
maintenance instructions.
Check hydraulic oil filter
When the filter gauge needle remains in the red
sector (while the engine is idling and the oil is at
service temperature), the filter must be replaced.
1. Stop the engine, switch off by-pass valve.
2. The old filter is removed by turning it clockwise
(use a filter strap wrench if necessary).
3. Tilting the power pack rearwards will minimise
oil spillage.
4. Before mounting the new filter, it is
recommended to grease the surface of the seal
with oil in order to ease tightening of the filter.
Every three months
Check tightness of nuts, bolts, screws and hose
fittings.
Clean the air cleaner element, see engine
manufacturer's handbook.
Every 300 hours or every
year
Change the hydraulic oil.
Wash the hydraulic tank.
Change the hydraulic oil filter.
For engine maintenance, see engine
manufacturer's handbook.
Safety and operating instructions LP 13-30 P
16 © Construction Tools EOOD | 3392 5254 01 | 2017-04-13
Original instructions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco LP 13-30 P and is the answer not in the manual?

Atlas Copco LP 13-30 P Specifications

General IconGeneral
BrandAtlas Copco
ModelLP 13-30 P
CategoryPower Pack
LanguageEnglish