Repair Instruction No. 169.2/94
PHE 24/26/30-Range
1 Remove the service cover (6).
2 Remove the strain relief (5).
3 Loosen the cable (4).
4 Lever off the six handle cover (Softgrip)
holders with aid of a screwdriver (see
illustration) and remove the softgrip (3)
5 Remove the screws of the handle
cover (2).
6 Remove the AVS-rubber (1).
Dismantling the
handle
1 Unhinge the tension springs (4) and put
them aside (don’t take them out!) and pull
out the carbon brushes (5).
2 Pull out the carbon brush holder (6).
3 Pull off the cable and remove the electrical
parts.
4 Remove the second handle cover (1), the
AVS-rubber (2), and the guide rollers (3).
Dismounting the
electrical parts
1 Remove the armature (4) with the end
shield (1) from the motor housing (5) (if
necessary expel it by hitting it lightly with
a plastic hammer).
2 Remove the end shield screws (2) (turn
armature until reliefs in the fan (3) release
the screws).
3 Expel the armature by hitting it lightly with
a plastic hammer.
Removing the
armature
13
12345
1
2
3
45 6
11
12
1
2
3
4563