STARTING/STOPPING
BEFORE STARTING
1. Before initial start-up, prepare battery for
operation if not already done. See section Battery
care.
2. With the compressor standing level, check the
level of the engine oil. Add oil, if necessary, to the
upper mark on dipstick. Consult the Engine
Operation Manual for the type and viscosity grade
of the engine oil.
3. Check the level of the compressor oil. See section
Compressor regulating system. The pointer of
oil level gauge (OLG) should register in the green
range. Add oil if necessary. See section
Lubrication oils for the oil to be used.
4. Check that the fuel tank contains sufficient fuel.
Top up, if necessary. Consult the Engine
Operation Manual for the type of fuel.
5. Drain any water and sediment from the fuel filter
until clean fuel flows from the drain cock.
6. Press vacuator valves (VV) of the air filters to
remove dust.
7. Check the air filter vacuum indicators (VI). If the
yellow piston reaches the red marked service
range, replace the filter element. Reset the
indicator by pushing the reset button.
8. Open air outlet valve to allow air flow to the
atmosphere.
Before removing oil filler plug (FP),
ensure that the pressure is released by
opening an air outlet valve.
CONTROL PANEL (WITH COLD START; OPTION)
Reference Name
P1 Hourmeter
PG Working pressure gauge
H1 Temperature alarm lamp (red)
H2 General alarm lamp (red)
S1 Start switch
S4 Lamp test button
S6 Cold start button
P1 PG H1
H2
S1
S6
S4
1023

Table of Contents