- 57 -
LIMITATIONS
1)
Compressor: PAROIL S i.s.o. PAROIL M
PAROIL 5W40 i.s.o. 15W40
Designation XA(S) 137 DD -
XA(S) 300 DD7
XA(S) 137 DDG -
XA(S) 300 DD7G
XAHS 107 DD -
XAHS 250 DD7
230/400 V (3 phase)
Minimum effective receiver pressure bar(e) 4 4 4
psi 58 58 58
Maximum effective receiver pressure, compressor
unloaded
bar(e) 8.5 8.5 13.5
psi 123 123 196
Maximum ambient temperature at
sealevel EC
standard °C 48 48 49
°F 118 118 120
aftercooler
option
°C 40 40 41
°F 104 104 106
Maximum ambient temperature at
sealevel NON EC
standard °C 53 53 53
°F 127 127 127
aftercooler
option
°C 45 45 45
°F 113 113 113
Minimum starting temperature °C - 10 - 10 - 10
°F 14 14 14
Minimum starting temperature, with coldstart equipment
1)
°C - 20 - 20 - 20
°F - 4 - 4 - 4
Altitude capability see curves

Table of Contents