- Auto button
When 'Inactive' is selected, pressing the Remote
button of the Xc2002 will have no effect.
When 'Active' is selected, pressing the Remote
button of the Xc2002 will toggle the Xc2002
between Local and Auto/Remote operation.
- Unit
This menu can be accessed to select units of
measure in either metric (°C, bar) or imperial (°F,
psi) units.
See also "Parameter list" on page 39 for selection
between metric (°C) or imperial (°F) units.
- Auto NoLoad
When "no" selected the unit will remain in unload
when not loaded for a certain time.
When "yes" selected the unit will switch to noload
when running unload for a certain time.
- ST1 Reset
- ST2 Reset
These views are the Service Timer resets. When
"Yes" is selected a customer level password will
be requested prior to approving the Service Timer
Reset.
When a service timer alarm occurs and is
acknowledged, the service timer will be reset
automatically.
- Diagnostics
When 'On' is selected, the Xc2002 will activate
the Power After Contact output (after 20s. delay),
to power up the engine electronics for diagnostic
purposes.
You can leave Diagnostics in three ways:
- change Diagnostics parameter back to 'Off'
- or by pressing the Stop button
- or by starting the machine (pressing Start button)
- Stationary Regeneration
When 'On' is selected, the Xc2002 will initiate a
Stationary Regeneration of the DPF.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XAHS 146 Dd S3B APP and is the answer not in the manual?

Atlas Copco XAHS 146 Dd S3B APP Specifications

General IconGeneral
BrandAtlas Copco
ModelXAHS 146 Dd S3B APP
CategoryAir Compressor
LanguageEnglish

Related product manuals