- 97 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation
XAMS 527 - XAMS 1150 XATS 487 - XATS 1050 XAHS 447 - XAHS 950 XAVS 407 - XAVS 900
Absolute inlet pressure bar(e) 1 1 1 1
psi 14.514.514.514.5
Relative air humidity % 0 0 0 0
Air inlet temperature °C 20 20 20 20
°F 68 68 68 68
Nominal effective working pressure bar(e) 8.6 10.3 12 14
psi 125 149 174 203
Designation
XAMS 527 - XAMS 1150 XATS 487 - XATS 1050 XAHS 447 - XAHS 950 XAVS 407 - XAVS 900
Minimum effective receiver pressure bar(e) 4 4 4 4
psi 58585858
Maximum effective receiver pressure, compressor
unloaded
bar(e) 10 11.7 13.4 13.4
psi 145 170 194 194
Maximum ambient
temperature at sea level
without aftercooler °C 50 50 50 50
°F 122 122 122 122
with aftercooler °C 45 45 45 45
°F 113 113 113 113
Minimum starting temperature °C -10 -10 -10 -10
°F 14 14 14 14
Minimum starting temperature, with coldstart
equipment
°C -25 -25 -25 -25
°F -13 -13 -13 -13
Altitude capability see separate curve on page 100