- 99 -
1)
Free air delivery is measured according to ISO 1217 ed.3 1996 annex D
Designation
XAMS 527 - XAMS 1150 XATS 487 - XATS 1050 XAHS 447 - XAHS 950 XAVS 407 - XAVS 900
- at unload Fuel expert kg/h 24.1 24.1 23.5 23.2
lb/h 53.9 53.9 52.6 51.8
No
Fuel expert
kg/h 24.1 24.1 23.5 23.2
lb/h 53.9 53.9 52.6 51.8
Specific fuel consumption g/m
3
24.02 26.1 28.14 30.9
- at 100% FAD lb/1000 cu.ft 1.50 1.63 1.76 1.93
Typical oil content of compressed air mg/m
3
< 3< 3< 3< 3
oz/1000 cu.ft < 0.003 < 0.003 < 0.003 < 0.003
Engine oil consumption (maximum) g/h 112.4 113.0 112.1 112.8
oz/h 3.96 3.98 3.95 3.98
Compressed air temperature at outlet valve °C 90 90 90 90
°F 194 194 194 194
Noise level
- Sound pressure level (LP), complies with ISO 2151/
EPA under free field conditions at 7 m distance
dB(A) 72 / 76 72 / 76 72 / 76 72 / 76
- Sound power level (LW) complies with 2000/14/EC dB(A) 100 100 100 100
- Sound power level (LW) complies with 84/533/EEC
and 85/406/EEC limits
dB(A) 104 104 104 104
Tolerance: +/- 5% 25 l/s (53 cfm) < FAD < 250 l/s (530 cfm)
+/- 4% 250 l/s (530 cfm) < FAD
The international standard ISO 1217 corresponds to
following national standards:
British BSI 1571 part 1
German DIN 1945 Part 1
Swedish SS-ISO 1217
American ANSI PTC9