EasyManua.ls Logo

Atlas Copco XAS96JD - Storage Procedures; Service Kits Information

Atlas Copco XAS96JD
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1310 3010 08 21
4.7.1 Electrolyte
ùù Read the safety instructions carefully
Electrolyte in batteries is a sulphuric acid solution in distilled
water.
The solution must be made up before being introduced into the
battery.
4.7.2 Recharging A Battery
Before and after charging a battery, always check the
electrolyte level in each cell; if required, top up with distilled
water only. When charging batteries, each cell must be open,
i.e. plugs and/or cover removed.
+ Use a commercial automatic battery charger
according to manufacturers instructions.
Apply with preference the slow charging method and adjust
the charge current according to the following rule of thumb:
battery capacity in Ah divided by 20 gives safe charging
current in Amp.
4.7.3 Battery Maintenance
Keep the battery clean and dry
- Keep the electrolyte level at 10 to 15 mm above the plates
or at the indicated level; top up with distilled water only.
- Keep the terminals and clamps tight, clean, and lightely
covered petroleum jelly.
4.8 Storage
Run the compressor regularly, e.g. twice a week, until warm.
Load and unload the compressor a few times to operate the
unloading and regulating components. Close the air outlet
valves after stopping.
+ If the compressor is going to be stored without
running from time to time, protective measures
must be taken as described In a separate Service
Bulletin (ASB), which may be obtained on request.
Consult Atlas Copco.
4.9 Service Kits
A service kit is a collection of parts to fit a specific repair or
rebuilding task.
It guarantees that all necessary parts are replaced at the same
time which improves the uptime of the unit.
The order numbers of the Service Kits are listed in the Atlas
Copco Parts List (ASL).
+ Contact Atlas Copco.