EasyManua.ls Logo

Atlas Copco ZR 110

Atlas Copco ZR 110
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjust the regulation valve setting at nominal pressure of the compressor (e.g. 7.0 bar) so that
the value of Nozzle Fraction is equal to the value between brackets for at least 5 minutes: NF =
40% +/-1%.
4. Lock the regulation valve.
5. Go to the main Elektronikon screen by pushing X repeatedly.
8.2 Before starting
The operator must apply all relevant Safety precautions.
If the water system has been drained, close the drain valves and fit the drain plugs or
pipe.
See section Stopping
The number of motor starts is programmed at maximum 3 per day.
To modify this setting, consult sections Modify parameters.
Oil level
Oil system components, ZR 110 up to ZR 275
Instruction book
2920 1815 04 261

Table of Contents

Related product manuals