11 Problem solving
11.1 Problem solving
Before starting any maintenance or repairs, stop the compressor.
Depressurize the air system as follows:
Close the air outlet valve.
On compressors equipped with Electronic Water Drains (EWD), press the
test buttons on top of the electronic water drains.
Press the emergency stop button.
Open the isolating switch (customer's installation) to switch off the voltage to the
compressor, and lock it (Lock Out - Tag Out procedure, LOTO).
Repairs inside the speed regulation cabinet must only be carried out by Atlas
Copco.
Apply all relevant safety precautions.
Wait at least 6 minutes before starting any electrical repairs as hazardous high
voltage remains on the condensers of the variable speed drive for 6 minutes after
switching off the voltage.
Control panel
Control panel of Elektronikon controller
Instruction book
2920 1815 04 293