ZT/ZR 110 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 144
400 135
500 109
690 79
ZT/ZR 110 compressors with oversized IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 153.8
400 146.1
500 116.9
690 83.7
ZT/ZR 110 compressors with oversized IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 144
400 135
500 109
690 79
ZT/ZR 132 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 153.8
400 146.1
500 116.9
690 83.7
ZT/ZR 132 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 156
400 146
500 118
690 86
ZT/ZR 132 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
Instruction book
300 2920 1815 04

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco ZR 110 and is the answer not in the manual?

Atlas Copco ZR 110 Specifications

General IconGeneral
BrandAtlas Copco
ModelZR 110
CategoryAir Compressor
LanguageEnglish

Related product manuals