12.0 Notes on EMC
12.1 Guidelines and Manufacturer's Declaration - Emissions
TheATMOSC401andATMOSC361areintendedforuseintheenvironmentspeciedbelow.Thecustomeroruser
of the ATMOS C 401 and ATMOS C 361 should ensure that it is used in such an environment.
Emissions Test Compliance Electromagnetic Environment - Guidance
Emissions of
harmonics
acc. to IEC 61000-3-2
Class A The ATMOS C 401 and ATMOS C 361 are
suitable for use in all establishments, including
domestic,
and those directly connected to the public
low-voltage power supply network that supplies
buildings used for domestic purposes.
Emissions of
Voltageuctuations/icker
IEC 61000-3-3
Corresponds
12.2 Guidelines and Manufacturer's Declaration - Immunity
TheATMOSC401andATMOSC361areintendedforuseintheelectromagneticenvironmentspeciedbelow.The
customer or user of the ATMOS C 401 and ATMOS C 361 should ensure that it is used in such an environment.
Immunity Test
IEC 60601- Test
Level
Compliance
Level
Electromagnetic Environ-
ment - Guidance
Electrostatic
discharge (ESD)
acc. to IEC 61000-4-2
± 6 kV Contact
± 8 kV Air
± 6 kV Contact
± 8 kV Air
Floors should be made of wood or
concrete or tiled with ceramic tiles.
Ifoorsaresynthetic,therelative
humidity should be
at least 30 %.
Fast
electrical transient/
bursts
IEC 61000-4-4
± 2 kV Mains
± 1 kV I/Os
± 2 kV Mains The quality of the supply voltage
should correspond to a typical
commercial or hospital environ-
ment.
Surges
IEC 61000-4-5
± 1 kV
Di󰀨erential
± 2 kV
Common
± 1 kV
Di󰀨erential
± 2 kV
Common
The quality of the supply voltage
should correspond to a typical
commercial or hospital environ-
ment.
Magneticeldat
power frequency
(50/60 Hz)
IEC 61000-4-8
3 A/m 3 A/m Powerfrequencymagneticelds
should be that of a typical com-
mercial or hospital environment.
■MedicalelectricalequipmentissubjecttospecialprecautionswithregardtoEMCandmustbeinstalledacc.
to following EMC notes.
■PortableandmobileRFcommunicationfacilitiescaninuencemedicalelectricalequipment.
■Theuseofotheraccessories,othertransducersandcablesthanstatedmayleadtoanincreasedemission
or a reduced interference immunity of the equipment or system.
The device may not be used directly next to other devices or piled up with other devices. If operation next to or piled
with other devices is necessary, please watch the device to check its intended operation in this arrangement.