TECHNICAL DATA
ATTACK boiler type Unit 9 12 15 20 25 30 35 40 45 50
Nominal output EKO, KLV, P kW
9 121520253035404549,9
Nominal input EKO, KLV, P kW
9,9 13,2 16,5 22 27,5 33 38,5 44 49,5 55
Number of elements pc
2 3 4567
Adjustable output PLQ, KLQ kW
5–9 12–15 15–20 18–25 24–30 28–35 38–45 42–49,9
Modulable output E, EZ kW
5–9 10–18 16–25 25–35 3045 33–49,9
Adjustable input PLQ, KLQ kW
5,5–9,9 13,2–16,5 16,5–22 19,8–24,5 26,4–33 30,8–38,5 41,8–49,5 46,2–55
Modulable input E, EZ kW
5,59,9 11–16,5 17,6–24,5 27,538,5 3349,5 36,3–55
Gas pressure in front of the boiler mbar
20
Diameter of nozzles mm
2,5 2,5 2,5 2,7 2,5 2,7 2,7 2,5 2,7 2,5
Pressure to nozzles – EKO, PLQ,
KLV, KLQ, P
kPa
0,8–1,4 0,95 0,7–1,05 0,8–1,2 0,8–1,35 1–1,35 0,7–1,15 1,35 0,85–1,15 0,85–1,25
Pressure to nozzles – E, EZ kPa
0,8–1,4 0,5–1,4 0,5–1,35 0,65–1,15 0,6–1,15 0,6–1,25
Fuel consumption by max. output
– EKO, PLQ, KLV, KLQ, P
m
3
/h
1,06 1,4 1,76 2,35 2,94 3,5 4,12 4,7 5,3 5,85
Fuel consumption by max. output
– E, EZ
m
3
/h
1,0 6 2,13 2,94 4,12 5, 3 5, 85
Fuel consumption by min. output
– EKO, PLQ, KLV, KLQ, P
m
3
/h
0,88 1,4 1,76 2,13 2,82 3,3 4,4 4,9
Fuel consumption by min. output
– E, EZ
m
3
/h
0,88—1,17—1,88—2,94 3,5 3,8
Fuel Natural gas „G 20“
Natural gas connection DN 15 (Pass through nut 3/4")
Flue exhaust diameter mm 110 135 145 165 180
Volume of the cast iron body l 7 10 13,8 16,8 19,8 22,8
Max. pressure in heating system bar PMS = 4
Connection of heating – forced
circulation / natural circulation (S, P)
G 1" / 6/4"
Boiler weight kg 73 99 125 151 180 208
Power supply V / Hz ~ 230 / 50
Grade of protection IP 40
Temperature of the heating
water
°C 40–90 / 0–90 (P)
Efficiency % 90
Flue gas flow g/s 14,4 20,5 28,9 37,2
Electrical input W 15