5.3.4 Configure the SIP Trunk IP Address
This step shows how to configure the Proxy Set toward SIP Trunk. The Proxy Set defines
the destination address (IP address or FQDN) of the IP entity server. Proxy Sets can also
be used to configure load balancing between multiple servers.
To configure Proxy Set:
1. Open the Proxy Sets table (Setup menu > Signaling & Media tab > Core Entities
folder >Proxy Sets).
2. Edit the Proxy Set 0 (you can identify it by the 'Proxy Name' field).
Parameter Value
Index
0
Proxy Keep-Alive
Using Options
a. Click the Proxy Address link located below the table; the Proxy Address table
opens.
b. Click New; the following dialog box appears:
Figure 5-10: Configuring Proxy Address for SIP Trunk
c. Configure the address of the Proxy Set per the parameters described in the table
below.
Parameter Value
Index
0
Proxy Address
uk.ic.sipconnect.hipcom.co.uk:5060 (SIP Trunk IP
address / FQDN and destination port)
Transport Type
UDP (Network transport type for the SIP Trunk)
d. Click Apply.