Page | 13
4. Attach to other end of the flexible shower hose to the “water OUT connection (middle
connection) on the water heater. Do not over tighten. Note that you can also apply Teflon
tape to this threaded connection to avoid leaks.
5. Connect the bayonet end of the gas hose to the bayonet fitting on the drawbar and turn on
the gas cylinder.
Operating the hot water system
1. It is preferable to set the BURNER control to LOW
2. IMPORTANT: It is important that when starting the appliance that the gas regulator is set to
the ‘min’ position.
3. IMPORTANT: It is important that when starting the appliance that the water regulator is set
to the ‘min’ position.