24 MX-series Inverters
Error type
Display
message
Error
code
Error description Action
Over DC
voltage
OV-DC
1020
The DC input of the solar
strings exceeds the
inverters limits.
1. Restart inverter (up to three times).
2. Contact installer to:
a. Perform independent measurement of string voltage to confirm that the
inverter reading is correct.
3. Rewire strings so that string voltage is within accepted range.
Over
temperature
TEM-PRO
1032
The internal
temperature of inverter
exceeds limits.
1. Check location of inverter. Ensure it has adequate ventilation and is not
exposed to direct sunlight.
2. Contact your installer to replace inverter if problem persists.
Short circuit
fault
SHORT-PRO
1030
A short circuit has been
detected in the system.
1. Restart inverter (up to three times).
2. Call installer to:
a. Check for pinched, crimped or otherwise damaged cables and
connections.
b. Check all switches for short circuit.
3. If error persists contact your installer for a replacement inverter.
Ground fault
GROUND-PRO
1033
Current flow detected
through ground
conductor.
1. Restart inverter (up to three times).
2. Call installer to:
a. Check if there is any current on the ground conductor using a clamp
meter.
b. Check for pinched, crimped or otherwise damaged cables and
connections.
3. If error persists contact your installer for a replacement inverter.
Current
leakage
ILeak_PRO
1034
A current leak has been
detected.
1. Restart inverter (up to three times).
2. Call installer to:
a. Check if there is any current on the ground conductor using a clamp
meter.
b. Check for pinched, crimped or otherwise damaged cables and
connections.
3. If error persists contact your installer for a replacement inverter.