Error description Action
Over DC
voltage
OV-DC
The DC input of the solar
strings exceeds the
inverters limits.
1. Restart inverter (up to three times).
a. Perform independent measurement of string voltage to confirm that the
inverter reading is correct.
3. Rewire strings so that string voltage is within accepted range.
The internal
temperature of inverter
exceeds limits.
1. Check location of inverter. Ensure it has adequate ventilation and is not
exposed to direct sunlight.
2. Contact your installer to replace inverter if problem persists.
1. Restart inverter (up to three times).
2. Call installer to:
a. Check for pinched, crimped or otherwise damaged cables and
connections.
b. Check all switches for short circuit.
3. If error persists contact your installer for a replacement inverter.
Current flow detected
through ground
conductor.
1. Restart inverter (up to three times).
2. Call installer to:
a. Check if there is any current on the ground conductor using a clamp
meter.
b. Check for pinched, crimped or otherwise damaged cables and
connections.
3. If error persists contact your installer for a replacement inverter.
Current
leakage
ILeak_PRO
1. Restart inverter (up to three times).
2. Call installer to:
a. Check if there is any current on the ground conductor using a clamp
meter.
b. Check for pinched, crimped or otherwise damaged cables and
connections.
3. If error persists contact your installer for a replacement inverter.