AutoStop Maxi User Manual Version 8.18 Page 8
3. TEST DATA STORAGE (OPTIONAL)
3.1 Using the Data Logger
The data logger has about 32K of memory available to store tests and allows you to
recall and either print or upload them to any IBM or IBM compatible computer at a
later time. Depending on the length of the tests, you can store up to 30 tests.
Preliminary Function To Press Screen Display
From the Ready> position,
press “L”. To recall the
data, press “R
Print the
Data
R
1) XXXX ( Reg no # desired is displayed
on the LCD. Then Press “C” for an
Customer Copy or “O” for a Official Copy.
From the Ready> position,
press “L”. To clear the
data, press “C
Clear the
Data
Logger
C Pressing “C“ will show “Clear all (Y/N)
Pressing “Y” will clear Data
Pressing “N” will not clear the data.
From the Ready> position,
press “L”. To display
storage status information,
press “I
Display
Data
Logger
storage
status
information
I
Tests saved: xx
Note: This screen displays the Number of
tests stored in the Data Logger. Press any
key to go to the next screen.
Mem: xx % used
Note: Data Logger memory usage in
percentage
3.2 Downloading Data
The downloadable model of the AutoStop Maxi is provided with a serial port to
attach to any IBM or IBM compatible computer with a spare COM port. An interface
cable and download software are required to download test results from the Brake
Meter. These are provided with the unit. The uploaded data, formatted as a text file,
can be imported into spreadsheet programs such as Excel and Lotus for further
detailed examination, or printed. Maxi Brake Meters are shipped with download
software (also available on the AutoTest website) for PCs running Windows
95/98/2000. Version 7.0 and greater Brake Meters require Version 1.4 of the
download software. Earlier version Brake Meters require Version 1.21 of the
download software. You will receive the appropriate software with the unit.
3.2.1 Download Instructions
If you have downloaded the software from the web, simply double-click on the
downloaded file to install the software. If you have received the software on CD,
insert the CD into your computer CD drive. If the setup program does not run
automatically, run the setup.exe program located on the CD to install the software.
After the program installation is finished, there will be two new icons on your
desktop.
Double-click on the 'Maxi Data Logger' icon to run the download software, or
double-click on the 'Maxi Data Logger Data' icon to access the directory containing