Chapter 3: Keypad Operation and Quickstart
3–16
Copy Keypad Function
The COPY KEYPAD function has the ability to permanently store up to four (4)
different program parameter settings within the keypad device. The stored
parameter settings can be for any of the DURA
PULSE AC Drives. This allows the
parameter settings to be backed-up and readily available for either duplicating the
same multiple AC drives or for maintenance use if a drive needs to be replaced.
Enable Copy Keypad Function
Press the PROGRAM key repeatedly until the COMMS GROUP, P9.00 - P9.42, is
displayed on the keypad LCD display.
Press the ENTER key to display the various parameters for this group.
Use the UP/DOWN keys to display parameter P9.40, the COPY KEYPAD function.
Press the ENTER key to display the
current value for this parameter.
Use the UP/DOWN keys to change the
value in this parameter to a “1”. A value
of “1” is used to enable the COPY
KEYPAD function.
Press the ENTER key to accept this value
and enable the COPY KEYPAD
function. The LCD display will indicate
“Value Accepted” for a moment.
The LCD display will automatically
increment to the next parameter in the
group.
It is recommended that once the application has been programmed, the parameter
settings be backed-up in the keypad for future use and maintenance.
DURAPULSE AC Drive User Manual
1st Ed. Rev. D 05/2013