6 Basic Operations (Counter/Timer/Communication)     
38    © Copyright Reserved Autonics Co., Ltd. 
6.1.2  Setting value check mode  
Setting value of setting mode can be confirmed using the    and    keys.   
6.1.3  Switching display function in preset indicator 
Setting value 1(PS1) and setting value 2(PS2) are displayed each time pressing    key in dual 
setting value change model. (In timer, it is available for OND, ONd1, ONd2 output mode.) 
6.1.4  RESET 
In RUN mode or function setting mode, if pressing    key or applying the signal to the RESET 
terminal on the back side, present value will be reset and output will maintain off status. When 
selecting voltage input (PNP), short no.10 and no. 12 terminals, or when selecting no-voltage 
input (NPN), short no.11 and no.12 terminals to reset. 
6.2  BATCH counter  
(only for CT6M-1P□□/CT6M-2P□□ model) 
BATCH counter displays the repeat same operation to the setting value. 
  In RUN mode, press the    key to enter BATCH counter indication mode.   
  In BATCH counter indication mode, 'BATCH counter value' is displayed in count indicator 
and 'BATCH counter setting value' is displayed in preset indicator. 
  In BATCH counter indication mode, press the    key to set BATCH setting value change 
mode.   
   
  Press the    key to return BATCH counter indication mode. 
※If setting BATCH counter setting value as ‘0’, BATCH output does not turn ON.   
※In BATCH counter indication mode, press the    key to return RUN mode.