7 Counter Mode
48 © Copyright Reserved Autonics Co., Ltd.
Input
mode
Counting chart
Down-1
[DN-1]
When INA input signal is rising ( ) , it counts.
INA: Counting input
INB: No counting input
Down-2
[
DN-2]
When INA input signal is falling ( ) , it counts.
INA: Counting input
INB: No counting input
Up/
Down-A
[UD-A]
INA: Counting input
INB: Counting command input
When INB is "L", counting command is up.
When INB is "H", it is counting command is down .
Up/
Down-B
[UD-B]
INA: Up counting input
INB: Down counting input
INA: When INA and INB input signals are rising ( ) at the same time,
it maintains previous counting value.