5 Counter mode     
40    © Copyright Reserved Autonics Co., Ltd. 
 
Prescale decimal 
point
※4
 
[SClDP] 
 
※Decimal point of prescale should not set smaller than decimal point [DP] 
Prescale value [SCL] 
※Setting range: 0.00001 to 99999.9   
※Setting range of prescale is linked with prescale decimal point [SClDP] 
 
  setting. 
TOTAL counter
※1
 
[TOTAL] 
 
Start point value 
[START] 
※Setting range of start point value is linked with decimal point [DP] 
setting.
 (0.00000 to 999999)   
※When input mode is DN, DN-1, DN-2, this parameter [START] does not   
appear.   
※When total count function is ON, this parameter [START] does not 
appear.
 
※1
 
Memory protection 
[DATA] 
 
※CLR: Resets the counting value when power OFF. 
     REC: Maintains the counting value when power OFF.   
  (memory protection) 
Key lock [LOCK] 
 
※lOFF: Unlock keys, key lock indicator turns OFF 
    LOc1: Locks      key, key lock indicator turns ON 
    LOc2: Locks  ,    key, key lock indicator turns ON 
    LOc3: Locks    ,
,    key, key lock indicator turns ON 
 
 
※1: This is for the voltage input(PNP)/no-voltage input(NPN) selectable model (CX6□-□□). 
※2: For free voltage input model(CX6□-□□F), these parameters do not appear due to fixed 
   setting. 
※3: For 1-stage setting model (CX6□-1P□□), OUT1 output time does not appear.   
The OUT2 output time is displayed as OUtT. 
※4: Decimal point and prescale decimal point 
  Decimal point 
: Set the decimal point for display value regardless of prescale value. 
  Prescale decimal point 
: Set the decimal point for prescale value of counting value regardless of display value.