5 Counter mode
40 © Copyright Reserved Autonics Co., Ltd.
Parameter
Parameter setting value
Prescale decimal
point
4
[SClDP]
Decimal point of prescale should not set smaller than decimal point [DP]
Prescale value [SCL]
Setting range: 0.00001 to 99999.9
Setting range of prescale is linked with prescale decimal point [SClDP]
setting.
TOTAL counter
1
[TOTAL]
Start point value
[START]
Setting range of start point value is linked with decimal point [DP]
setting.
(0.00000 to 999999)
When input mode is DN, DN-1, DN-2, this parameter [START] does not
appear.
When total count function is ON, this parameter [START] does not
appear.
1
Memory protection
[DATA]
CLR: Resets the counting value when power OFF.
REC: Maintains the counting value when power OFF.
(memory protection)
Key lock [LOCK]
lOFF: Unlock keys, key lock indicator turns OFF
LOc1: Locks key, key lock indicator turns ON
LOc2: Locks , key, key lock indicator turns ON
LOc3: Locks ,
, key, key lock indicator turns ON
1: This is for the voltage input(PNP)/no-voltage input(NPN) selectable model (CX6-□□).
2: For free voltage input model(CX6-□□F), these parameters do not appear due to fixed
setting.
3: For 1-stage setting model (CX6-1P□□), OUT1 output time does not appear.
The OUT2 output time is displayed as OUtT.
4: Decimal point and prescale decimal point
Decimal point
: Set the decimal point for display value regardless of prescale value.
Prescale decimal point
: Set the decimal point for prescale value of counting value regardless of display value.