8
Note: The 960F control uses Factor A and Capacity
settings to calculate the actual system capacity. If the
actual system capacity is in excess of 9999 gallons
(99.99 cubic meters) the control will display 9999
(99.99) until the water usage has dropped the
remaining capacity below that number. When water is
flowing through the system, the colon in the Time of
Day display will blink.
To complete the initial programming of the 960F,
proceed to the Level II Parameters.
Table 1 - Level I Programming Parameters
Parameter
Range of
Values
Minimum
Increments
Default
Units of
Measure
Notes
Name Description
P1
Time of day
AM or PM
1:00 to 12:59
00:00 to 23:59
1 None Hour: minute
Range depends on value selected for
P13. Enter the current time.
P2
Time of day of
backwash
1:00 to 12:59
AM or PM
00:00 to 23:59
1 2:00 AM Hour: minute
Range depends on value selected for
P13. Skip this parameter to accept the
default or enter a new time.
P3 Factor A
3 to 250
30 to 2500
1
10
10
100
U.S.
Metric
Unit of measure depends on value
selected for P12. Set to 10 (100 for
metric units) for proper operation.
P4 Factor B
0.2 to 51.0
0.1 to 25.5
0.2
0.1
0.2
0.1
U.S.
Metric
Unit of measure and default depends
on value selected for P12. Set to .5
(.1 for metric units) for proper 960i
operation.
P5
Capacity of
unit
0.1 to 140.0
0.01 to 14.00
0.1
0.01
1.0
0.1
Gallons/100
Cubic Meters/
10
Unit of measure depends on value
selected for P12. Enter the unit
capacity in gallons/100 (cubic meters/
10 if metric units).