System Characteristics
System Description, Autroprime Interactive Fire Detection System, 116-P-APRIME-SYSTEMD/XGB 2007-10-10,
Autronica Fire and Security AS
Page 7
EN 54-2
Clause
Imple-
mented
Option text Description/Requirement Autroprime functionality
10 Yes Test
condition
Testing the processing and
indication of fire alarm signals
from zones.
11 No Standardized
input/output
interface
Standardized input/output
interface, suitable for the
transmission and reception of
signals to and from ancillary
equipment.
Communication options
available. Serial line
protocol to cover required
functionality in 11a) and
11b) to be defined. See
also ancillary function list.
12.5 Yes Integrity of
transmission
paths
12.5.3 and 12.5.4. c.i.e. in more
than one cabinet.
Operator panel may be
separated from the main
cabinet, additional operator
panels on a panel bus.
2.5.2 Functions relating to other parts of EN 54
EN 54 part no Description
EN 54-4 Power supply equipment Battery internal resistance and deep discharge.
2.5.3 Ancillary functions not required by this European Standard
Ancillary function Description
Supervisory condition Condition for monitoring ancillary equipment related to life, safety
or property protection.
Pre Alarm condition A warning level from the detectors with zone indication on display.
Point info. available. Implemented as a condition in line with those
required by the standard.
Self Verifying Function An automatic, calibrated test of all detectors, interfaces,
connections and cables for 300- and 500-series equipment. Series
200 without SV.
DYFI+ Dynamic Filtering, introduced in our BS-100 c.i.e., further
enhanced in AutroSafe and Autroprime.
Environmental Adaptivity Autroprime detectors may be programmed for environments,
clean, normal, industrial.
SOLAS functionality Mandatory functional requirements given by Safety Of Life At Sea
(SOLAS) for installations on ships.
Dependency on more than one
alarm signal
As defined in proposal for new EN 54-2 (Type C dependency).
Repeater panels Alarm indication and silence/reset buttons.
(In accordance with Annex G, an ancillary function without
requirements. See also above option: 11 Standardised
input/output interface)
Information panel Event indication only. (Comment as for Repeater panel).
Loop units short circuit isolators Communication path between neighbouring loop units may be
isolated in case of short circuit or break. Provided connection as a
loop (recommended), no loop units will be lost in case of such a
fault.
Alarm zones Means of sub-dividing the alarming area in an installation during
fire alarm condition

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autronica Autroprime BS-200M and is the answer not in the manual?

Autronica Autroprime BS-200M Specifications

General IconGeneral
BrandAutronica
ModelAutroprime BS-200M
CategoryFirefighting Equipment
LanguageEnglish

Related product manuals