AUX DC Inverter Free Match 50HZ R32
186
◇ Adjust the relative position of the suspension hook on the suspension bolt so that the unit can
be in level position in all directions. Check with a level gauge after installation to ensure that the
indoor unit is horizontal, otherwise it will cause water leakage, air leakage etc.
◇ Tighten the bolt and ensure that four hooks are in close contact with the nuts and washers, to
fix the indoor unit under the ceiling.
◇ After the unit is installed ensure it is secure and does not shake or sway.
◇ Ensure that the center of the indoor unit is in alignment with the center of the opening in the
ceiling.
4.4 Drainage pipe installation
The drainage pipe should be properly insulated to prevent the generation of condensation.
Heat insulation material: the thickness of rubber insulation pipe should be more than 8mm