30
Spe
cial attention
Most Indoor Unit temperature sensors of the frequency conversion
machine have a resistance value of 20KΩ.
Do not use improper sensor during repairing and maintenance, or it
may led to the start of anti-frosting or overheat protection mode due to
wrong temperature sensing of the machine.
In case a sensor with the resistance value over 20KΩ is used, the
detected temperature will be much lower than the actual temperature,
which may lead to the high pressure of cold-blast protection system
during the heating process, or the frequent start of anti-freezing
protection during the cooling process.
n case a sensor with the resistance value below 20KΩ is used, the
detected temperature will be much higher than the actual temperature,
which may lead to the frequent start of overheat protection mode
during the heating or the overload protection during the cooling
process.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX Q Series and is the answer not in the manual?

AUX Q Series Specifications

General IconGeneral
RefrigerantR32
Energy Efficiency Class CoolingA++
Energy Efficiency Class HeatingA+
TypeSplit System
FeaturesSleep Mode, Turbo Mode, Self-Cleaning
Energy Rating5 Star
Filter TypeAnti-Bacterial Filter
Warranty5 Years
Cooling Capacity12000 BTU/h
Heating Capacity12000 BTU/h

Related product manuals