1. Place the scale on a flat, stable surface. Level the scale using the leveling bubble at the lower le
side of the display.
2. With the weighing plaer empty, turn on power switch (located underneath on the right-hand
side of the scale). Due to the high resoluon of this scale, allow 10 minutes for the scale to warm
up before use for opmum results.
3. Press the ON/OFF key to power on the scale. The self-check will run and the scale will display a
zero reading. The scale is now ready for weighing.
NOTE: If the scale does not zero, an error code will be displayed. See Troubleshoong to resolve.
4. To change the weighing unit of measure, press the UNIT key to toggle between kg, lb, or oz.
5. Set the TARE weight if desired.
6. Place objects on the scale plaer and read the weight on the indicator.
7. When finished weighing, press the ON/OFF key for 4 seconds to power off the scale.
1. Under the normal weighing mode, press ZERO key to set the scale to zero point when the scale
reading is stable (the weighing unit light without shining).
2. When under the TARE mode, ZERO key is invalid.
NOTE: If the scale cannot be zeroed, an error code will be displayed. See Troubleshoong to resolve.
1. Place an empty container on the plaer and press the TARE key. The display will return to zero,
eliminang the weight of the container. The ZERO LIGHT will go off and the TARE LIGHT will be lit.
NOTE: The gross weight must be posive to enter a weighed tare.
2. To clear the weighed tare, remove all weight from the scale. The display will show a negave weight.
Press the TARE key to return the display to zero, eliminang the weight of the container. The TARE
LIGHT will go off and the ZERO LIGHT will be lit.
1. Use the number keys to input the tare weight. Your entry will be displayed in the UNIT PRICE display
window. Then press the TARE key to confirm or press the ON/OFF key to exit and not confirm.
EXAMPLE: With the plaer empty, entering 100g and pressing the TARE key will display “-0.100” kg.
2. To recall the previously stored tare weight, press the RC.PLU key. Press the ON/OFF key to return to
weighing.
NOTE: The previously stored tare weight can only be recalled with the RC.PLU key when in tare
seng mode.
3. To clear the manually entered tare weight, press the TARE key to confirm.
4. If unit price is in un-saved mode, the tare weight and unit price will be auto cleared aer transacon
and objects being moved.
OPERATIONS & SETTINGS
7.
NORMAL WEIGHING MODE
ZERO FUNCTION
TARE FUNCTION
This scale allows for both a manually entered pre-set tare weight, as well as a “weighed” tare weight.
WEIGHED TARE
PRE-SET TARE