Maintenance
Interior
Use warm water and a mild soap with a clean cloth to wipe down the interior of the unit.
DO NOT use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior
finish.
Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the
frame of the door, soak in warm water and soap for thirty (30) minutes, dry with soft cloth,
and replace.
Check door gaskets for proper seal after they are replaced.
Periodically remove the shelves and pilasters from the unit and clean them with mild soap and
warm water. To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift
the pilaster up and out.
Cleaning the Condenser Coil
A dusty condenser may lead to high energy consumption, less cooling eectiveness, and
compressor damage.
For ecient operation, keep the condenser surface free of dust, dirt, and lint.
We recommend cleaning the condenser coil at least once per month.
The condenser coil is located at the bottom behind the panel.
Cleaning the Condenser Coil Instructions
1.
Disconnect the electrical power from the unit.
2.
Remove the front cover and base cover with a screwdriver.
3.
Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a
vertical direction.
4.
Clean the condenser with a commercial condenser coil cleaner, available from any
kitchen equipment retailer. Ex. Noble Chemical Tech Line Coil Cleaners (148TLECCCLNR,
148TLHDCCLNR, 148TLECOILDD, 148TLFMCCLNR, 147TLEVPCLNR, or 147TLHDCCLNR).
5.
After cleaning, straighten any bent condenser fins with a fin comb.
6.
When finished, be sure to reinstall the front cover and base cover.
7.
Reconnect the electrical power to the unit.