Modular Ice Machine User’s Manual
- 1 -
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
194MC35022FA, 194MC35022HA, 194MC42022FA, 194MC42022HA, 194MC50030FA,
10/2021
User Manual
User Manual
194MC50030HA, 194KMC350B2F, 194KMC350B2H, 194KMC420B2F,
194KMC420B2H, 194KMC500B3F, 194KMC500B3H, 194BIN23022, 194BIN27530,
194KMC350L2F, 194KMC350L2H, 194KMC420L2F, 194KMC420L2H, 194KMC500L3F,
194KMC500L3H, 194BIN40022, 194BIN54030, 194KMC350H2F, 194KMC350H2H,
194KMC420H2F, 194KMC420H2H, 194KMC500H3F, 194KMC500H3H, 194HBN12022,
194HBN18030

Questions and Answers

  • T
    Thomas WileyAug 19, 2025
    Why is my Avantco 194KMC350L2F too slow in making ice?
    • B
      Beverly LiAug 20, 2025
      If your Avantco Ice Maker is making ice too slowly, several factors could be at play. Ensure the condenser and air filter are clean. High ambient temperatures or poor ventilation around the unit can also slow down ice production; the normal working temperature range is 41-95°F. Water temperature should also be within 41-95°F. Check these elements to optimize ice production.
  • S
    Stacey GordonAug 22, 2025
    How to reduce noise of Avantco Ice Maker?
    • S
      sandovaljonathanAug 22, 2025
      If your Avantco Ice Maker is making too much noise, ensure it is placed on a leveled foundation and that the unit itself is properly leveled.
  • M
    Mariah PerezAug 25, 2025
    What to do if the display shows E06 high pressure protection on Avantco 194KMC350L2F?
    • M
      Michael OrozcoAug 25, 2025
      If your Avantco Ice Maker displays an E06 error, indicating high pressure protection, check the fan and correct it if it doesn't start. Also, check and correct the high pressure switch wires.
  • E
    Eric WarrenAug 26, 2025
    Why is the ice defrost abnormal in my Avantco Ice Maker?
    • J
      Justin BlanchardAug 26, 2025
      Abnormal ice defrost in your Avantco Ice Maker can be due to several reasons: * The ambient temperature might be too low; the normal working temperature range is 41-95°F. * The defrost valve may not be starting normally; check and correct the defrosting valve. * The ice thickness might be set too thin or too thick; check and correct the ice thickness setting.
  • S
    Sabrina MorganAug 27, 2025
    What to do if Avantco 194KMC350L2F display shows E04 high temperature?
    • J
      Jenna GriffinAug 27, 2025
      If your Avantco Ice Maker displays an E04 error, indicating high temperature, the condenser may be dirty. Clean the condenser.
  • I
    ireyesAug 29, 2025
    Why does my Avantco 194KMC350L2F shut down every 3 minutes after startup?
    • L
      Linda KhanAug 29, 2025
      If your Avantco Ice Maker shuts down every 3 minutes after startup, the ambient temperature may be too high. The normal working temperature range is 41-95°F.
  • E
    Elizabeth ParrishSep 1, 2025
    What to do if indicator is OFF on Avantco 194KMC350L2F Ice Maker?
    • A
      anthony97Sep 1, 2025
      If the indicator is off on your Avantco Ice Maker, check the plug and socket to ensure they are properly connected.
  • C
    Cynthia WilliamsSep 3, 2025
    What to do if my Avantco 194KMC350L2F shows E06 high pressure protection?
    • D
      Dr. Nicole LittleSep 3, 2025
      If your Avantco Ice Maker displays the error code E06 indicating high pressure protection, it could be due to the fan not starting. Verify the fan and correct any issues. Also, check the high pressure switch wires and correct if necessary.
  • W
    William SmithSep 5, 2025
    Why is ice defrost abnormal in my Avantco Ice Maker?
    • T
      Trevor ThomasSep 5, 2025
      If your Avantco Ice Maker's ice defrost is abnormal, it might be due to several reasons. The ambient temperature could be too low; ensure it's within the normal working range of 41-95°F. Also, the defrost valve may not be starting normally, so check and correct the defrosting valve. Finally, the ice thickness might be set incorrectly; check and correct the ice thickness setting.
  • L
    lararobertSep 7, 2025
    Why does my Avantco 194KMC350L2F shutdown every 3 minutes?
    • L
      Laura ThomasSep 7, 2025
      If your Avantco Ice Maker shuts down every 3 minutes after startup, it could be because the ambient temperature is too high. The normal working temperature range is 41-95°F.