Undercounter Ice Machine
Users Manual
- 1 -
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.

194UC77BA, 194UC120A, 194UC160FA, 194UC160HA, 194UC210FA,
194UC210HA, 194UC280FA, 194UC280HA
User Manual

Questions and Answers

  • L
    Luke JohnsonAug 9, 2025
    What to do if my Avantco 194UC160HA shows E06 high pressure protection?
    • V
      vincent29Aug 9, 2025
      If your Avantco Ice Maker displays the error code E06 indicating high pressure protection, it could be due to the fan not starting. Verify the fan and correct any issues. Also, check the high pressure switch wires and correct if necessary.
  • D
    Debra HebertAug 15, 2025
    What to do if Avantco 194UC160HA display shows E04 high temperature?
    • J
      Jason CarlsonAug 15, 2025
      If your Avantco Ice Maker displays E04 indicating a high temperature issue, the condenser may be dirty or blocked. Clean the condenser to resolve this. Ensure that high pressure switch wires are properly connected.
  • A
    Andrew ClarkAug 21, 2025
    Why is ice defrost abnormal in my Avantco 194UC160HA Ice Maker?
    • L
      landradeAug 21, 2025
      If your Avantco Ice Maker's ice defrost is abnormal, it might be due to several reasons. The ambient temperature could be too low; ensure it's within the normal working range of 41-95°F. Also, the defrost valve may not be starting normally, so check and correct the defrosting valve. Finally, the ice thickness might be set incorrectly; check and correct the ice thickness setting.
  • T
    Tyler WhiteAug 28, 2025
    Why does my Avantco Ice Maker shutdown every 3 minutes?
    • T
      Troy HintonAug 28, 2025
      If your Avantco Ice Maker shuts down every 3 minutes after startup, it could be because the ambient temperature is too high. The normal working temperature range is 41-95°F.
  • M
    Miranda BakerSep 2, 2025
    What to do if indicator is OFF on Avantco 194UC160HA?
    • C
      charles43Sep 3, 2025
      If the indicator light on your Avantco Ice Maker is off, check the plug and socket to ensure they are properly connected.

Summary

Warning and Safety

Installation

Control Panel

Ice cube thickness adjustment

Details how to adjust the thickness of the ice cubes.

Other Special Protection - Shutdown

Fault code and its comments

Lists fault codes, their descriptions, and corresponding machine actions.

Maintenance

Clean Function

Manual Cleaning & Sanitizing

Detailed instructions for manually cleaning and sanitizing the ice machine.

Service Call

Troubleshooting

Not working

Addresses the fault of the machine not operating at all.

Indicator is OFF

Troubleshooting steps for when the indicator light is off.

Shutdown every 3 minutes after startup

Diagnosing and fixing shutdowns occurring shortly after startup.

The display shows E04 high temperature

Troubleshooting steps for E04 high temperature fault.

Ice defrost abnormal

Resolving issues with the ice defrost cycle.

Poor transparency of ice cubes; ice cubes too thin or incomplete

Avantco 194UC160HA Specifications

General IconGeneral
Model194UC160HA
TypeUndercounter Ice Maker
Power Supply115V
Voltage115V
Hertz60 Hz
Phase1
ApplicationCommercial
Condenser TypeAir Cooled
Drain Connection3/4"
Ice Production Capacity160 lb. per day
Water Connection3/4"