Modular Ice Machine User’s Manual
- 1 -
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
194MC35022FA, 194MC35022HA, 194MC42022FA, 194MC42022HA, 194MC50030FA,
10/2021
User Manual
User Manual
194MC50030HA, 194KMC350B2F, 194KMC350B2H, 194KMC420B2F,
194KMC420B2H, 194KMC500B3F, 194KMC500B3H, 194BIN23022, 194BIN27530,
194KMC350L2F, 194KMC350L2H, 194KMC420L2F, 194KMC420L2H, 194KMC500L3F,
194KMC500L3H, 194BIN40022, 194BIN54030, 194KMC350H2F, 194KMC350H2H,
194KMC420H2F, 194KMC420H2H, 194KMC500H3F, 194KMC500H3H, 194HBN12022,
194HBN18030

Questions and Answers

  • D
    Dr. Kyle MeyerAug 18, 2025
    Why is my Avantco 194MC50030HA Ice Maker too slow in making ice?
    • R
      Richard ChanAug 18, 2025
      If your Avantco Ice Maker is making ice too slowly, several factors could be at play. Ensure the condenser and air filter are clean. High ambient temperatures or poor ventilation around the unit can also slow down ice production; the normal working temperature range is 41-95°F. Water temperature should also be within 41-95°F. Check these elements to optimize ice production.
  • M
    Mark WallaceAug 20, 2025
    How to reduce noise of Avantco 194MC50030HA?
    • L
      Lori LewisAug 20, 2025
      If your Avantco Ice Maker is making too much noise, ensure it is placed on a leveled foundation and that the unit itself is properly leveled.
  • J
    Jessica BaldwinAug 23, 2025
    What to do if the display of Avantco 194MC50030HA Ice Maker shows E06 high pressure protection?
    • L
      Laura Smith MDAug 23, 2025
      If the display of your Avantco Ice Maker shows 'E06 high pressure protection', it indicates an issue with the fan. First, check and correct the high pressure switch wires. Also, check and correct the fan itself.
  • H
    Heidi MorrowAug 25, 2025
    Why does Avantco 194MC50030HA Ice Maker make ice cubes with poor transparency, too thin or incomplete?
    • T
      Taylor WelchAug 26, 2025
      If your Avantco Ice Maker is producing ice cubes that are not transparent, too thin, or incomplete, several factors could be responsible. Ensure that the ice thickness setting is correct. Also, verify that the water supply pressure is within the range of 1.3 bar to 5.5 bar. The water temperature should be within the normal working range of 41-95°F. Additionally, inspect the inlet water valve for proper function. Check the inlet water valve for blockages and ensure there are no water leaks.
  • J
    Jeffrey SpencerAug 27, 2025
    Why does Avantco 194MC50030HA shutdown every 3 minutes after startup?
    • V
      vincentkevinAug 27, 2025
      If your Avantco Ice Maker shuts down every 3 minutes after startup, it may be due to the ambient temperature being too high. The normal working temperature range for the unit is 41-95°F.
  • C
    Christopher TaylorAug 30, 2025
    What to do if the display of Avantco 194MC50030HA Ice Maker shows E04 high temperature?
    • J
      Joseph ReidAug 30, 2025
      If the display of your Avantco Ice Maker shows E04 high temperature, it could be due to a dirty and blocked condenser. Clean the condenser to resolve this issue.
  • W
    wheelerkyleSep 1, 2025
    Why is ice defrost abnormal in Avantco Ice Maker?
    • P
      Patrick RobersonSep 1, 2025
      If your Avantco Ice Maker's ice defrost is abnormal, several factors could be the cause. If the ambient temperature is too low, ensure it is within the normal working range of 41-95°F. Check and correct the defrosting valve if it's not starting normally. If the ice thickness is too thin or too thick, check and correct the ice thickness setting.
  • V
    valenzuelashelbySep 4, 2025
    What to do if indicator is OFF on Avantco 194MC50030HA Ice Maker?
    • T
      Tonya AbbottSep 4, 2025
      If the indicator light on your Avantco Ice Maker is off, check the plug and socket to ensure they are properly connected.
  • D
    Dawn MooreSep 7, 2025
    What to do if my Avantco 194MC50030HA Ice Maker shows E06 high pressure protection?
    • D
      Daniel AbbottSep 7, 2025
      If your Avantco Ice Maker displays the error code E06 indicating high pressure protection, it could be due to the fan not starting. Verify the fan and correct any issues. Also, check the high pressure switch wires and correct if necessary.
  • J
    Jason PopeSep 9, 2025
    What to do if Avantco 194MC50030HA display shows E04 high temperature?
    • A
      Alyssa SilvaSep 9, 2025
      If your Avantco Ice Maker displays E04 indicating a high temperature issue, the condenser may be dirty or blocked. Clean the condenser to resolve this. Ensure that high pressure switch wires are properly connected.

Summary

Warning and Safety

Operation

Startup and Operation

Procedures for startup and confirming normal ice machine operation.

Service and Troubleshooting

Service Call Procedures

Steps to check before calling for ice machine service.

Dispenser Setup and Operation

Initial Startup and Use

Procedures for initial startup, checks, and ice dispensing.

Dispenser Care and Maintenance

General Care and Cleaning

Regular inspection, cleaning, and sanitizing of the ice dispenser.

Dispenser Service Diagnosis

Troubleshooting Common Issues

Diagnosing and resolving common dispenser faults: no ice, leaks, lights.

Avantco 194MC50030HA Specifications

General IconGeneral
Ice TypeHalf Dice
Voltage115V
Hertz60 Hz
Phase1
RefrigerantR404A
Water Connection3/4 inch