Questions and Answers

  • P
    Paula TuckerAug 18, 2025
    Why is my Avantco 194MC50030FA Ice Maker too slow in making ice?
    • T
      Timothy ThomasAug 18, 2025
      If your Avantco Ice Maker is making ice too slowly, several factors could be at play. Ensure the condenser and air filter are clean. High ambient temperatures or poor ventilation around the unit can also slow down ice production; the normal working temperature range is 41-95°F. Water temperature should also be within 41-95°F. Check these elements to optimize ice production.
  • P
    perezrhondaAug 20, 2025
    How to reduce noise of Avantco Ice Maker?
    • T
      tracyhuffmanAug 20, 2025
      If your Avantco Ice Maker is making too much noise, ensure it is placed on a leveled foundation and that the unit itself is properly leveled.
  • W
    William DicksonAug 23, 2025
    What to do if the display of Avantco 194MC50030FA shows E06 high pressure protection?
    • M
      mark05Aug 23, 2025
      If the display of your Avantco Ice Maker shows 'E06 high pressure protection', it indicates an issue with the fan. First, check and correct the high pressure switch wires. Also, check and correct the fan itself.
  • T
    Thomas BlackAug 26, 2025
    Why does Avantco 194MC50030FA Ice Maker make ice cubes with poor transparency, too thin or incomplete?
    • J
      Jared BrownAug 26, 2025
      If your Avantco Ice Maker is producing ice cubes that are not transparent, too thin, or incomplete, several factors could be responsible. Ensure that the ice thickness setting is correct. Also, verify that the water supply pressure is within the range of 1.3 bar to 5.5 bar. The water temperature should be within the normal working range of 41-95°F. Additionally, inspect the inlet water valve for proper function. Check the inlet water valve for blockages and ensure there are no water leaks.
  • R
    Robert ClarkeAug 28, 2025
    Why does Avantco Ice Maker shutdown every 3 minutes after startup?
    • J
      Julie BurnettAug 28, 2025
      If your Avantco Ice Maker shuts down every 3 minutes after startup, it may be due to the ambient temperature being too high. The normal working temperature range for the unit is 41-95°F.
  • C
    Carolyn RomanAug 30, 2025
    What to do if the display of Avantco 194MC50030FA shows E04 high temperature?
    • J
      James SmithAug 31, 2025
      If the display of your Avantco Ice Maker shows E04 high temperature, it could be due to a dirty and blocked condenser. Clean the condenser to resolve this issue.
  • H
    Harold RodriguezSep 2, 2025
    Why is ice defrost abnormal in Avantco 194MC50030FA Ice Maker?
    • L
      Linda AdamsSep 2, 2025
      If your Avantco Ice Maker's ice defrost is abnormal, several factors could be the cause. If the ambient temperature is too low, ensure it is within the normal working range of 41-95°F. Check and correct the defrosting valve if it's not starting normally. If the ice thickness is too thin or too thick, check and correct the ice thickness setting.
  • X
    xreedSep 4, 2025
    What to do if indicator is OFF on Avantco Ice Maker?
    • D
      Debbie SchmittSep 4, 2025
      If the indicator light on your Avantco Ice Maker is off, check the plug and socket to ensure they are properly connected.
  • R
    ryan04Sep 7, 2025
    What to do if my Avantco Ice Maker shows E06 high pressure protection?
    • M
      Melissa BradfordSep 7, 2025
      If your Avantco Ice Maker displays the error code E06 indicating high pressure protection, it could be due to the fan not starting. Verify the fan and correct any issues. Also, check the high pressure switch wires and correct if necessary.
  • B
    Bryce Nichols MDSep 9, 2025
    What to do if Avantco Ice Maker display shows E04 high temperature?
    • N
      nguyenvictoriaSep 10, 2025
      If your Avantco Ice Maker displays E04 indicating a high temperature issue, the condenser may be dirty or blocked. Clean the condenser to resolve this. Ensure that high pressure switch wires are properly connected.

Summary

Warning and Safety

Installation

Installation Steps

A step-by-step guide to follow during the ice machine installation process.

Startup and Operation

Operation Instructions

Detailed instructions on how to operate the ice machine during normal use.

Control Panel

Control Panel Features

Description of LED display, lamps, and ice thickness adjustment.

Maintenance

Cleaning Procedures

Service Call

Troubleshooting

Installation-Plumbing

Installation-Electrical and Assembly

Initial Start Up and Operation

General Care and Cleaning

Service Diagnosis

Limited Service Warranty

Avantco 194MC50030FA Specifications

General IconGeneral
Model194MC50030FA
Power SupplyElectric
Width30 inches
Voltage115V
Hertz60 Hz
Phase1
TypeIce Maker
Product TypeModular
Depth24.5 inches
RefrigerantR-404A
CertificationETL Sanitation