B. System Specifications
13
Table 3. Other Specifications
Specification Value
Switch Fabric ■ Full digital, nonblocking
Electrical
Specifications
■ 35 Watts (120 BTUs/hr.) per ACS processor module during normal power
consumption
■ 45 Watts (154 BTUs/hr.) per ACS processor module during maximum
power consumption
■ 10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power
consumption
■ 25 Watts (90 BTUs/hr.) per 206 module during normal power
consumption
■ 35 Watts (120 BTUs/hr.) per 206 module during maximum power
consumption
■ 30 Watts (105 BTUs/hr.) per 308EC module during normal power
consumption
■ 40 Watts (140 BTUs/hr.) per 308EC module during maximum power
consumption
■ 10 Watts (35 BTUs/hr.) per 1600 DSL module during normal and
maximum power consumption
■ U.S., Canada, and other 110V countries:
– ACS processor module and one 206 module (2-Slot carrier) = 2.3
Amps max. current, full system capacity
– ACS processor module and four 206 modules (5-Slot carrier) = 4
Amps max. current, full system capacity
■ Countries using 220V:
– ACS processor module and one 206 module (2-Slot carrier) = 1.2
Amps max. current, full system capacity
– ACS processor module and four 206 modules (5-Slot carrier) = 2
Amps max. current, full system capacity
■ 45 days to 6 months memory backup with 2 AAA-size standard alkaline
batteries (IEC LR03)
Processor Module
Specifications
■ 68306 16 Mhz processor
■ 256 Kbyte RAM
■ 512 Kbyte FLASH ROM
■ Custom VLSI DSP ASIC–16 bit, 52 Mhz
– VLSI = Very Large Scale Integration
– DSP = Digital Signal Processor
– ASIC = Application Specific Integrated Circuit
Extension Jack
Specifications
(206 module)
■ Ringing voltage: +5 VDC, -140 VDC peak to peak; trapezoidal wave
shaping
■ 35- to 38-Volt talk battery
■ Ringing frequency: 20 Hz