INTRODUCTION
The AF994 is a 4 zone wall-mounting burglar alarm control panel. The 4 zones have NC-type inputs; the
alarm detectors can be connected to these directly by wire. A tamper line is also provided to protect all
the external elements. The mechanical key, located on the front side permits the system to be connected
and disabled. Four pushbuttons are provided to permit exclusion of the individual zones, so that the
system can be partially connected.
A remote activation point can also be connected, code AF45342, which through the electronic key
AF45339, permits connection, disconnection and zoning from a remote position. The control panel is
complete with an internal power supply unit that powers the detectors, charges the batteries of the out-
door self-powered siren and charges the back-up battery. This latter, inside the control panel, powers the
system in the event of mains failure.
TECHNICAL DATA
• Enclosure: White ABS (300x255x90) mm
• Power supply: 230Vac ± 10%
• Maximum mains rating : 160 mA
• 4 NC-type alarm zones
• NC-type tamper line
• Incorporated mechanical key
• 4 pushbuttons for zone exclusion
• Possibility of connecting an external electronic key for inserting/zoning
• Entrance time, referred to zone A1, adjustable through micro-switches: 2-15-30-60 s.
• Auxiliary open-collector alarm output to control the telephone dialler
• Output for self-powered siren control. N.C. contact normally connected to V +
• Output for auxiliary siren control. N.A. contact normally connected to V+ in alarm conditions
• Internal power supply unit with two outputs:
– 13.8vdc for system power supply and internal battery charging
– 14.5vdc for self-powered siren battery
• Maximum current the power supply unit can deliver: 800mA
• Battery: 12v / 6.5Ah Pb
Climatic conditions
The requirements and performance of the control panel according to the CEI 79-2 standard are assured
under the following climatic conditions:
• Reference temperature and relative humidity: 25°C RH 60%
• Operating room temperature range: -10°C to +50°C
• Maximum relative humidity: 90% at +35°C
• Altitude: 2000m a.s.l.
Reference standards
Conforms to standard CEI 79.2 1st level, to the general emission standard CEI-EN50081-1 and immunity
standard CEI-EN50130-4 for electromagnetic compatibility and to standard CEI-EN60950 for electrical