44
3INSTALLATION AND DEINSTALLATION
3.2 CONNECTING THE SENSORS
ALS
20X
256
3.2.2
Alternative label sensor
Other suitable sensors can be used as an alternative to
the throughbeam photoelectric sensor.
Permitted sensor types: PNP or NPN
Default setting: PNP
Alternative label sensor and standard photo-
electric sensor may both be connected at the
same time. Selection of the active sensor is
done by calling the function MACHINE SETUP >
Label sens. type. The setting is stored within the
product profile.
Connecting the sensor
Plug the sensor in to the connector shown [51A]
(ALS 256: [51B]).
Pin assignment
1) chapter “Changing light/dark switching at the product sensor or the
alternativ label sensor” on page 47
Connection accessories Article no.
Connector (cable-Ø 4-6 mm) A8142
Connector (cable-Ø 6-8 mm) A8143
Connecting cable (coupling-plug) A7127
Pin Assignment
1+24V
2 +24 V or ground or no
connection
1)
3Ground
4 Sensor signal
[51] Connection for alternative label sensor:
A ALS 20X
B ALS 256
AB
12
34