AVL DiTEST Counter
Working with the AVL DiTEST Counter
21
User manual
Fig. 18
Information
If the measured value immediately exceeds double the limit value, after the probe has
been inserted into the exhaust, measurement procedure may be aborted, and the test
was not passed.
Information
If stabilization does not meet the requirements, an error message appears.
The measurement has been performed and the final result is shown on the LC display. If
the final result is less than or equal to the limit value, the test is passed. If the final result is
greater than the limit value, the test was not failed.
Fig. 19
Fig. 20
Information
The measurement result can be printed by connecting a printer to the device.