34 ESP-4 MI Serial Hub Installer/User Guide
You may also reboot the hub using the configuration utility (see Rebooting the Hub on page 42) or
the RESET button on the front panel (see Resetting on page 10).
Reinitializing the Hub
The Initialize operation resets all configurable values to their factory defaults, including the IP
address and password.
To reinitialize:
1. Click Re-initialize from the Main Menu.
2. Click the Reinitialize button.
After the reinitialization completes, the browser will try to reconnect to the hub, using the
predefined IP address (192.1.1.1). If this fails, or if the web interface does not return within 30
seconds, direct your browser to the predefined IP address (192.1.1.1).
You may also reinitialize the serial hub using the configuration utility (see Reinitializing the Hub
on page 42) or the INIT button on the front panel (see Reinitializing on page 10).