IMPORTANT: Observe all governing codes and ordinances.
• It is the customer’s responsibility to contact a qualified
electrical installer.
• A 120 Volt, 60 Hz, AC only, fused electrical supply is
required on a 15-amp circuit.
• DO NOT have a fuse in the neutral or ground circuit.
• The 3-prong outlet should be grounded. If the power cord
plug is not used, the power cord’s green wire should be connected to ground. Check
with a qualified electrician if you are not sure that the range hood is properly
grounded.
• DO NOT ground to a gas pipe.
• The range hood must be connected with copper wire/plug only.
• The range hood should be connected directly to the fused disconnect (or circuit
breaker) box through flexible armored or non-metallic sheathed copper cable. ETL
listed strain relief must be provided at each end of the power supply cable.
Specifications