16
Factory Restore
Factory Restore ( Menu Code: 5 )
To reset the balance back to factory settings:
Action Description Display Status Menu
Level
Press and Hold
[ MENU ]
1. Press and hold the MENU key for 5
seconds.
1.
Press [MENU]
Four Times
2. Press the MENU key four times to
change to Factory Conguration
menu. (CONFIG)
5.
Press [CAL] 3. Press the CAL key to enter the Basic
Function Setup menu.
5.1
− Press the UNIT key to move the cursor
− Press the PRINT key to increment the number
− Enter the code: 8888
Press [CAL] 4. Press the CAL key to conrm and
return to the previous menu
5
Press [TARE]
Twice
5. Press the TARE key twice to return to
regular weighing mode.
Print Data Format
TYPE: 20002
ID: 1
TEMP: 26.8C
BAT: FULL(EXT)
-----------------------
MODE:NORMAL
REF: 1000.00g
STATUS:STEADY
TARE:NONE
ZERO:NATURAL
WT:0.00G
----COMPLETE----
SIGNATURE:
Conguration Code
Device ID
Ambient Temperature
Power Status
Division
Application Mode
Calibration Mass
Stability Status
Tare Status
Zero Status
Weight Result
End of Data
Signature