AXISD2110-VESecurityRadar
Areamonitoringprofile
1.GotoRadar>Settings>Coexistence.
2.Setthenumberofneighboringradarsto3–5.
3.Selectagroupforyourradar.
Thisisanexampleofhowtogroupmultipleradarsinstalledside-by-sideinthesamecoexistencezone.
SeeAreainstallationexamplesonpage6formoreexamplesofinstallationswithmultipleradars.
Areainstallationexamples
Createavirtualfencewithmultipleradars
Tocreateavirtualfence,forexamplealongoraroundabuilding,youcanplacemultipleradarsside-by-side.Werecommendplacing
themwith100m(330ft)spacing.
Toavoidinterferencewhenyoumountmorethantworadarsinthesamecoexistencezone,setthenumberofneighboringradarsin
thedeviceinterface.Additionally,whenyoumountmorethanthreeradars,addeachradarintoagroup.
Youcanadjustthevirtualfencetocovercornersaswell,asillustratedinthisexample.
6